Napco Security Alarm
GEM-P3200 a popular, all-around 8 zone hybrid control expandable to 32 zones or 48 wireless points.
Features:
8 End-of-line-resistor burglary zones programmable for area, exit/entry delay, interior, follower, day zone, chime, fire options, sensor watch, swinger shutdown, zone ANDing and a variety of other features
Up to 48 points of up to 32 zones with optional zone-expansion modules 4- zone keypad EZMs (built-in)
Including up to 2 2-wire fire zones
Up to 32 individually coded users, each with a programmable authority level
3 on-board relay outputs, expandable 24 external relay outputs
3 keypad panics: fire, police & auxiliary
2 independent area partitions
Up to 7 separate access stations by up to 32 users
Up to 24 separately-addressable X-10 devices with the GEM-X10KIT
English-language prompts & system status messages from choice of keypad (8) models
User-customized zone descriptions, reprogrammable as required
2-wire and 4-wire smoke detectors
Reports alarms, restores and troubles by zone
255 event schedule
800 event log
Overview mode permits monitoring and control of total system from one keypad
2 programmable entry delay times
Interior-bypass group
Dynamic battery test interrupts charging and places battery under load every four hours
Chime by zone; programmable duration
Non-volatile RAM retains memory during power losses
Quick loader programmable
Auto-Download log
Exclusive V.A.L.I.D. feature (verifying automatic line integrity diagnostic) reduces false alarms due to changes in line resistance
Specifications:
Operating temperature: 0-49ยบC (32-120ยบF)
Input power: 16.5Vac via class 2 plug-in 40VA transformer
Loop voltage: 10-13Vdc
Loop current: 2.5mA with 2.2ohm end-of-line resistor (model EOL2.2K); 5mA for 2-wire smoke-detector zones
Loop resistance: 300W max.; 50W for 2-wire smoke detector zones
Relay outputs (burglary; reset; aux): wet, 12Vdc, 1.2A max.; dry (cut related jumper for dry contacts), SPDT contacts 24Vdc, 2A, 0: 6 PF
Auxiliary power output: 12Vdc regulated
Remote power output: 12Vdc regulated (for keypads)
650 mA combined standby current: (remote power + aux. power + reset relay power)
Standby time: residential fire/burglary & commercial burglary, 4 hours min.
EZM module: GEM-EZM8: Input, 50mA (including PGM output. PGM output: 5mA, 12V special application
Keypad current: GEM-RP1CAe2: 100mA; 35mA if backlighting is disabled (cut W1, W2 & W3) PGM Output: 5mA, 12V special application
Maximum number of keypads: 7. Maximum wiring length for each run (#22AWG): 1000โ divided by total number of keypads & EZMs on run
Designer keypad dimensions: 4 3/8โ x 5 7/8โ x 1 1/6โ (HWD); 11.1cm x 14.9cm x 2.7cm (HWD)
Specifications for Napco Security Alarm NAPGEM-P3200
Other Specs
Alternate Codes115694, GEM-P3200, GEMP3200
CategoryAccess Control, Alarms & Intercom, Burglar Alarms, Control Panels/Keypads
Part TypeControl Panel