Access Power Controller Board Only, Output 12/24VAC/DC, (4) 2.5Amp Fused Relay Outputs, FAI Fire Alarm Interface, LED Visual Indicators

$98.99

Brand:  Altronix
Part Number: ALXACM4
SKU: ALXACM4
In Stock (Denver): 2

In stock

Guaranteed Safe Checkout

Part Number: ALXACM4

Manufacturer:  Altronix

Series Overview

Notice: The info below is not item specific.

Altronix


ACM4 converts one 12 to 24 VAC or VDC input into four independently controlled fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an access control system, card reader, keypad, push button, PIR, etc. ACM4 will route power to a variety of access control hardware devices including mag locks, electric strikes, magnetic door holders, etc. Outputs will operate in both fail-safe and/or fail-secure modes. Units are designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two totally independent power sources, one providing power for board operation and the other for lock / accessory power. The FACP Interface enables emergency egress, alarm monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four outputs.

Features:

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the four (4) outputs.
  • Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input. b) Polarity reversal input from FACP signaling circuit.
  • FACP output relay (form “C” contact rated @ 1A 28VDC not evaluated by UL).
  • Removable terminal blocks facilitate ease of installation.

Specifications:

  • Input Voltage: 12 to 24 VAC or VDC operation (setting not required), 0.4A @ 12V, 0.2A @ 24V current consumption with all relays energized. Main fuse is rated at 10A/32V
  • Output:
    • Four independently controlled outputs:
      • Four fail-safe and/or fail-secure power outputs.
      • Four dry form “C” 5A rated relay outputs.
      • Any combination of the above.
    • Four auxiliary power outputs (unswitched).
    • Output ratings:
      • Fuses are rated 2.5A each.
      • Main fuse is rated at 10A.
      • Note: Total output current is determined by the power supply, not to exceed a maximum of 10A. total.
  • Temperature Operating: 0ºC to 49ºC (32ºF to 120ºF)
  • Relative Humidity: 85% +/– 5%
  • Dimensions (LxWxH): 5.175” x 3.36” x 1.25” (131.4mm x 85.3mm x 31.8mm)
  • Product Weight: 0.35 lb. (0.16 kg)

Specifications

Specifications for Altronix ALXACM4

Other Specs

Alternate CodesACM4
CategoryAccess Control, Alarm Power Supplies, Alarms & Intercom, Burglar Alarms, CCTV Products, Power Supplies, Wire & Power Supplies

Category: Access Control, Alarm Power Supplies, Alarms & Intercom, Burglar Alarms, CCTV Products, Power Supplies, Wire & Power Supplies